|
|
Venues (Conferences, Journals, ...)
|
|
GrowBag graphs for keyword ? (Num. hits/coverage)
Group by:
The graphs summarize 26 occurrences of 22 keywords
|
|
|
Results
Found 25 publication records. Showing 25 according to the selection in the facets
Hits ?▲ |
Authors |
Title |
Venue |
Year |
Link |
Author keywords |
63 | Sankararaman Suryanarayanan, Andrew Karellas, Srinivasan Vedantham, Sandra M. Waldrop, Carl J. D'Orsi |
A Perceptual Evaluation of JPEG 2000 Image Compression for Digital Mammography: Contrast-Detail Characteristics. |
J. Digit. Imaging |
2004 |
DBLP DOI BibTeX RDF |
contrast-detail, image compression, breast cancer, Digital mammography, JPEG 2000 |
56 | Alice N. Averbukh, David S. Channin, Prasobsook Homhual |
Comparison of Human Observer Performance of Contrast-Detail Detection Across Multiple Liquid Crystal Displays. |
J. Digit. Imaging |
2005 |
DBLP DOI BibTeX RDF |
contrast-detail, perception, observer, LCD, phantom |
41 | Hilde Bosmans, Kim Lemmens, Jürgen Jacobs, Beatrijs Verbrugge, Koen Michielsen, Federica Zanca, Joris Nens, Chantal Van Ongeval, Guy Marchal |
Comparative Technical Study of Two Generations of CR Plates for Digital Mammography. |
Digital Mammography / IWDM |
2008 |
DBLP DOI BibTeX RDF |
contrast - detail, digital mammography, computed radiography |
37 | E. Norrman, M. Gårdestig, J. Persliden, Håkan Geijer |
A Clinical Evaluation of the Image Quality Computer Program, CoCIQ. |
J. Digit. Imaging |
2005 |
DBLP DOI BibTeX RDF |
CDRAD phantom, computed calculated image quality figure, contrast-detail curves, image quality |
31 | Kristina Bliznakova, Giovanni Mettivier, Paolo Russo, Ivan Buliev |
Contrast Detail Phantoms for X-ray Phase-Contrast Mammography and Tomography. |
Digital Mammography / IWDM |
2016 |
DBLP DOI BibTeX RDF |
|
22 | Ioannis Delakis, Robert Wise, Lauren Morris, Eugenia Kulama |
Comparative Performance Evaluation of Contrast-Detail in Full Field Digital Mammography (FFDM) Systems Using Ideal (Hotelling) Observer versus Automated CDMAM Analysis. |
Digital Mammography / IWDM |
2014 |
DBLP DOI BibTeX RDF |
|
22 | Celia J. Strudley, Kenneth C. Young |
Evaluation of a New Design of Contrast-Detail Phantom for Mammography: CDMAM Model 4.0. |
Digital Mammography / IWDM |
2014 |
DBLP DOI BibTeX RDF |
|
22 | Chuen-Horng Lin, Chih-Yang Lin, Yu-Jung Cheng, Yung-Kuan Chan |
An automatic evaluation system for contrast-detail phantom images in digital radiography. |
Int. J. Imaging Syst. Technol. |
2012 |
DBLP DOI BibTeX RDF |
|
22 | Marco Bertolini, Andrea Nitrosi, Giovanni Borasi, Andrea Botti, Davide Tassoni, Roberto Sghedoni, Giulio Zuccoli |
Contrast Detail Phantom Comparison on a Commercially Available Unit. Digital Breast Tomosynthesis (DBT) versus Full-Field Digital Mammography (FFDM). |
J. Digit. Imaging |
2011 |
DBLP DOI BibTeX RDF |
|
22 | Nadia Oberhofer, Alessandro Fracchetti, Elvina Nassivera, Aldo Valentini, Ehrenfried Moroder |
Comparison of Two Novel FFDM Systems with Different a-Se Detector Technology: Physical Characterization and Phantom Contrast Detail Evaluation in Clinical Conditions. |
Digital Mammography / IWDM |
2010 |
DBLP DOI BibTeX RDF |
|
22 | Pedro Collado-Chamorro, Camilo Sanz-Freire, José Gómez-Amez, Alejandro Vázquez-Galiñanes, Natalia Lopo-Casqueiro, Maria González-De La Puente |
Contrast Detail Curves on Digital Mammography: Performance Comparison of Raw and Filtered Images. |
Digital Mammography / IWDM |
2010 |
DBLP DOI BibTeX RDF |
|
22 | Qirong Zhang, John Rong, Xizeng Wu, Yuhua Li, Wei R. Chen, Hong Liu 0003 |
Impacts of Filtration on Contrast-Detail Detectability of an X-ray Imaging System. |
Int. J. Biomed. Imaging |
2006 |
DBLP DOI BibTeX RDF |
|
22 | Qirong Zhang, Yuhua Li, Ben Steele, Wei R. Chen, Xizeng Wu, John Cheung, Hong Liu 0003 |
Contrast-detail Analysis of a CMOS-based Digital X-ray Imaging System. |
CATA |
2004 |
DBLP BibTeX RDF |
|
22 | Pavle Torbica, Wolfgang Buchberger, M. Bernathova, Ammar Mallouhi, Siegfried Peer, Hilde Bosmans, Keith Faulkner |
Comparative visualization of digital mammograms on clinical 2K monitor workstations and hardcopy: a contrast detail analysis. |
Medical Imaging: Image-Guided Procedures |
2003 |
DBLP DOI BibTeX RDF |
|
22 | Siegfried Peer, Iris Steingruber, Eva Gassner, Regina Peer, Salvatore M. Giacomuzzi |
Resolution requirements for monitor viewing of digital flat-panel detector radiographs: a contrast detail analysis. |
Medical Imaging: Image-Guided Procedures |
2002 |
DBLP DOI BibTeX RDF |
|
22 | Siegfried Peer, Ulrich Neitzel, Salvatore M. Giacomuzzi, Regina Peer, Eva Gassner, Iris Steingruber, Werner Jaschke |
Comparison of Low-Contrast Detail Perception on Storage Phosphor Radiographs and Digital Flat Panel Detector Images. |
IEEE Trans. Medical Imaging |
2001 |
DBLP DOI BibTeX RDF |
|
22 | Nicholas J. Hangiandreou, Kenneth A. Fetterly, Joel P. Felmlee |
Optimization of a contrast-detail-based method for electronic image display quality evaluation. |
J. Digit. Imaging |
1999 |
DBLP DOI BibTeX RDF |
|
22 | Ellen Shaw de Paredes, Panos P. Fatouros, Stefan Thunberg, Joanne F. Cousins, John Wilson, Tiffany Sedgwick |
Evaluation of a Digital Spot Mammographic Unit Using a Contrast Detail Phantom. |
Digital Mammography / IWDM |
1998 |
DBLP DOI BibTeX RDF |
|
10 | Ann-Katherine Carton, Hilde Bosmans, C. Vanongeval, Geert Souverijns, Guy Marchal, Jürgen Jacobs, D. Vandenbroucke, Herman Pauwels, K. Nijs |
Contrast Threshold of 4 Full Field Digital Mammography Systems Using Different Measurement Methods. |
Digital Mammography / IWDM |
2006 |
DBLP DOI BibTeX RDF |
|
7 | Jessie Q. Xia, Joseph Y. Lo |
Mass detectability in dedicated breast CT: A simulation study with the application of volume noise removal. |
BIBE |
2008 |
DBLP DOI BibTeX RDF |
|
7 | Håkan Geijer, Mats Geijer, Lillemor Forsberg, Susanne Kheddache, Patrik Sund |
Comparison of Color LCD and Medical-grade Monochrome LCD Displays in Diagnostic Radiology. |
J. Digit. Imaging |
2007 |
DBLP DOI BibTeX RDF |
liquid crystal display, monitor, medical imaging, PACS, image quality, displays, digital imaging, luminance |
7 | Nikhil Gupta 0001, M. N. S. Swamy, Eugene I. Plotkin |
Despeckling of medical ultrasound images using data and rate adaptive lossy compression. |
IEEE Trans. Medical Imaging |
2005 |
DBLP DOI BibTeX RDF |
|
7 | Ricardo José Ferrari, Robin Winsor |
Digital Radiographic Image Denoising Via Wavelet-Based Hidden Markov Model Estimation. |
J. Digit. Imaging |
2005 |
DBLP DOI BibTeX RDF |
Medical image denoising, hidden Markov model, digital radiography, wavelet denoising |
7 | K. Chakrabarti, R. V. Kaczmarek, Jerry A. Thomas, Alex Romanyukha |
Effect of Room Illuminance on Monitor Black Level Luminance and Monitor Calibration. |
J. Digit. Imaging |
2003 |
DBLP DOI BibTeX RDF |
Black level, image contrast, image surround, illuminance, luminance, diffuse reflection |
7 | Alice N. Averbukh, David S. Channin, Michael J. Flynn |
Assessment of a Novel, High-Resolution, Color, AMLCD for Diagnostic Medical Image Display: Luminance Performance and DICOM Calibration. |
J. Digit. Imaging |
2003 |
DBLP DOI BibTeX RDF |
AMLCD evaluation, DICOM Part 14 calibration, PACS, image display |
Displaying result #1 - #25 of 25 (100 per page; Change: )
|
|